Installation process of cold storage plate——The installation of the angle plate

Mar 06, 2018

With the renewal of cryopreservation technology. The antennae of the cold storage project has penetrated into more fields. The increase in the number of cold storage is the increasing demand of the Cold Storage Panel. Kalshine for you to provide quality Cold Storage Panel welcome caller inquire +86 18805179187. Today, let's talk about the installation of the Cold Storage Panel.

Installation process of cold storage plate——The installation of the angle plate

A seal is made on both sides of the corner plate of the cold storage and the contact of the plate. The angle between the wall panels should be fixed in section so as to facilitate the site pouring of polyurethane foam. Fixed roof angle plates should be every 500mm with iron cut a gap (the gap size for into foam material, then prevail) fixed on the top plate and the wall. The angle plate is fixed with the pull rivet, and the distance between the pulling rivet should be kept at 100mm. The pull rivet fixed on the angle of the package should be a straight line and the distance is equal. Pay attention to drilled rivets and pull riveting to grab the fixed pull rivets. The tools used should be perpendicular to the angle plate.

 

from: http://www.kalshine.com/produt/pu-panel/cold-storage-panel.html